<body><script type="text/javascript"> function setAttributeOnload(object, attribute, val) { if(window.addEventListener) { window.addEventListener('load', function(){ object[attribute] = val; }, false); } else { window.attachEvent('onload', function(){ object[attribute] = val; }); } } </script> <div id="navbar-iframe-container"></div> <script type="text/javascript" src="https://apis.google.com/js/platform.js"></script> <script type="text/javascript"> gapi.load("gapi.iframes:gapi.iframes.style.bubble", function() { if (gapi.iframes && gapi.iframes.getContext) { gapi.iframes.getContext().openChild({ url: 'https://www.blogger.com/navbar.g?targetBlogID\x3d8968604820003269863\x26blogName\x3dChemical+%26+Process+Technology\x26publishMode\x3dPUBLISH_MODE_BLOGSPOT\x26navbarType\x3dBLUE\x26layoutType\x3dCLASSIC\x26searchRoot\x3dhttps://webwormcpt.blogspot.com/search\x26blogLocale\x3den\x26v\x3d2\x26homepageUrl\x3dhttp://webwormcpt.blogspot.com/\x26vt\x3d6505904876529004088', where: document.getElementById("navbar-iframe-container"), id: "navbar-iframe", messageHandlersFilter: gapi.iframes.CROSS_ORIGIN_IFRAMES_FILTER, messageHandlers: { 'blogger-ping': function() {} } }); } }); </script>

Chemical Process Technology

Continue to learn tips, knowledge and experience about Chemical Process Technology...

Enter your email address:


CLOSE WINDOW


 

Chemical & Process Technology

A place to share knowledge, lesson learnt...

Monday, October 6, 2008

Display problem ? Click HERE

Subscribes to FREE Hydrocarbon Processing

A system may operate in two (2) modes operation. Mode 1 involve water and mode 2 involve air. Both conditions may lead to over-pressure of the system and it is protected by a pressure relief valve (PSV). The PSV is located 10 meter above the a vessel designed to ASME Section VIII with design pressure of 20 barg. How shall we determine the set pressure and maximum permissible line loss of the PSV ?

Only Non-Recoverable loss includes in PSV inlet line loss
PSV inlet line NON-RECOVERABLE losses shall be limited to 3% of set pressure. This requirement comes from ASME Section VIII, Div 1, Appendix M and also found in API RP-520 Part II. NON-RECOVERABLE losses is mainly the line frictional loss exclude the static pressure loss.

Why not include the static pressure loss in inlet line loss ?
The main reason is any difference in static pressure between the PSV and the protected system has been accounted for during selection of PSV set pressure. For example, a vessel with design pressure of 10 barg protected by PSV located 10 meter higher than the vessel, the static loss is approximately 1 bar (for water). The PSV set pressure shall not more than 10-1 = 9 barg.

Determine set pressure with maximum fluid density & static difference
Whenever determining the set pressure for a PSV involving vapor and liquid relief, the fluid with highest density (water in this case) shall be considered first.

Case studies
Refer to above...

Mode 1 : Water

Water density = 1000 kg/m3 (approx.)
Design pressure = 20 barg
Static pressure loss = 10 x 9.81 x 1000 / 100000 = 0.981 bar.

Maximum Set pressure of PSV = Design pressure - Static pressure loss
Maximum Set pressure of PSV = 20 - 0.981 = 19.019 barg.
Fix Set pressure of PSV at 19 barg (instead of 20 barg)
PSV starts to open at 19 barg when operating pressure at vessel is 20 barg.

PSV relieving pressure = 110% x 19 barg = 20.9 barg (lower than Maximum Allowable Relieving pressure of 22 barg).

Maximum Line loss = 3% of Set pressure = 3% x 19 bar = 0.57 bar.
Maximum PSV Reseat pressure = 19 - 0.57 = 18.43 barg.


Mode 2 : Air
Air density = 26 kg/m3 (approx.)
Design pressure = 20 barg
Static pressure loss = 10 x 9.81 x 26 / 100000 = 0.025 bar (~ Negligible)

From mode 1, Set pressure of PSV is 19 barg.
PSV starts to open at 19 barg when operating pressure at vessel is 19 barg.
Thus maximum operating pressure is only 19 barg.

Concluding Remarks
Static pressure loss affecting the PSV set pressure whilst only non-recoverable line loss to be taken for PSV inlet line loss. Ths concept is simple however mistake is always made in this area.

Related Posts

Labels: ,

posted by Webworm, 5:54 PM

1 Comments:

Anonymous Inlet Protection said...

Good info posted here. I learned some stuff about PSV that I didn't know prior to reading this.
-Jack

May 27, 2010 at 4:15 PM  

Post a Comment

Let us know your opinion !!! You can use some HTML tags, such as  <b>, <i>, <a>

Subscribe to Post Comments [Atom]

Home:

<< Home