<body><script type="text/javascript"> function setAttributeOnload(object, attribute, val) { if(window.addEventListener) { window.addEventListener('load', function(){ object[attribute] = val; }, false); } else { window.attachEvent('onload', function(){ object[attribute] = val; }); } } </script> <div id="navbar-iframe-container"></div> <script type="text/javascript" src="https://apis.google.com/js/platform.js"></script> <script type="text/javascript"> gapi.load("gapi.iframes:gapi.iframes.style.bubble", function() { if (gapi.iframes && gapi.iframes.getContext) { gapi.iframes.getContext().openChild({ url: 'https://www.blogger.com/navbar.g?targetBlogID\x3d8968604820003269863\x26blogName\x3dChemical+%26+Process+Technology\x26publishMode\x3dPUBLISH_MODE_BLOGSPOT\x26navbarType\x3dBLUE\x26layoutType\x3dCLASSIC\x26searchRoot\x3dhttps://webwormcpt.blogspot.com/search\x26blogLocale\x3den\x26v\x3d2\x26homepageUrl\x3dhttp://webwormcpt.blogspot.com/\x26vt\x3d6505904876529004088', where: document.getElementById("navbar-iframe-container"), id: "navbar-iframe" }); } }); </script>

Chemical Process Technology

Continue to learn tips, knowledge and experience about Chemical Process Technology...

Enter your email address:


CLOSE WINDOW


 

Chemical & Process Technology

A place to share knowledge, lesson learnt...

Thursday, February 28, 2008

Display problem ? Click HERE


A question raised related to Design temperature (Td) and Maximum Allowable Working Pressure (MAWT).

"I understood that Maximum Allowable Working Pressure (MAWT)
  • is the temperature where the vessel material will fail by its internal (design) pressure due to reduced at elevated temperature
  • is subject to vessel wall thickness. MAWT should be same or higher than design temperature (DT) as fabricated wall thickness would be thicker due to material available in the market or shop or some conservative calculation roundup.
  • Allowable stresses are same from-20F to 650 F (-29C to 343 C)
Is the vessel is fit from -29 C to 343 C ? Can we declare design temperature of 343 degC ?"
Above analysis is pretty correct to some extent. However, it is not the complete story about the design temperature and MAWT.

MAWT for tank is subject to vessel/tank wall thickness. Above analysis has covered most (if not all) points. However, there are other devices and fitting like flange, instrument, nozzle, etc attached to the vessel and possibly, the MAWT of these devices and fittings are much lower than the MAWT of tank. We shall always refer MAWT for SYSTEM instead of a particular equipment / instrument.

Hence the design temperature of the system is come into the picture ?
As mentioned above, MAWT for equipment, instrument, piping, etc are different. Design temperature for a system is what the process demand, MAWT is what the equipment / device can take. MAWT for ALL equipment, instrument, fittings, etc within a SYSTEM shall equal or more than the design temperature as specified by process engineer.

Related Post
WebWorm
Continue receive FREE stuff & Update.......Subscribe by Email OR RSS
Any comments / advices ?..........Drop it in comment field (below) or send a private email to me...

Labels:

posted by Webworm, 11:19 PM

0 Comments:

Post a Comment

Let us know your opinion !!! You can use some HTML tags, such as  <b>, <i>, <a>

Subscribe to Post Comments [Atom]

Home:

<< Home